14304 nagrania 894 konferencje 3766 wykładowców Zrealizuj voucher

Uzyskaj dostęp do najwyższej jakości wiedzy medycznej. Zarejestruj się »

  The imbalance between proliferation and apoptosis contributes to degeneration of aortic valves and bioprostheses

Autorzy: Izabela Tuleta1, Abdel Karim Al Ghaddioui1, Gerhard Bauriedel2, Nicolas Wernert3, Claus Jürgen Preusse4, Armin Welz4, Georg Nickenig1, Dirk Skowasch1 1 - Department of Internal Medicine II — Cardiology, Angiology and Pulmonology, University of Bonn, Bonn, Germany
2 - Department of Internal Medicine III — Invasive Cardiology and Cardiovascular Prevention, Hospital of Schmalkalden, Schmalkalden, Germany
3 - Department of Pathology, University of Bonn, Bonn, Germany
4 - Department of Cardiac Surgery, University of Bonn, Bonn, Germany

Abstrakt

Background: The pathomechanisms underlying aortic valve degeneration are incompletely understood. Therefore, the aim of our work was to assess the quantitative changes of proliferation and apoptosis accompanied by cellular phenotype alternations and matrix secretion in aortic sclerotic and stenotic valves and degenerative bioprostheses, as well as to detect the expression pattern of the rapamycin receptor FKBP12 across these three valve types.

Methods: Mild-to-moderate sclerotic and stenotic valves and degenerative bioprostheses from 30 patients (n = 10 per group) were collected at autopsy or by surgery. Ki67+, FKBP12+, alpha-actin+, HSP47+ and TUNEL+ apoptotic cells were analyzed by immunohistochemistry.

Results: The main finding was the reduced proliferation and increased apoptosis in stenotic valves (ST) compared to the sclerotic ones (SC) (proliferation: ST: 20.8 ± 2.0% vs. SC: 30.1 ± 2.2%, apoptosis: ST: 40.7 ± 5.0% vs. SC: 28.0 ± 5.1%, p < 0.05, respectively). Analogical alternations were found in degenerative bioprostheses (BP) (proliferation: 4.8 ± 2.3%; apoptosis: 13.1 ± 6.8%). Corresponding changes were observed in the valve cellularity (ST: 893 ± 168, SC: 1034 ± 284, BP: 385 ± 179 cells/mm2, p < 0.05, respectively). The FKBP12 signaling was reduced in diseased valves and bioprostheses (ST: 28.1 ± 3.6%, SC: 42.2 ± 3.8%, BP: 5.8 ± 1.9%, p < 0.05, respectively). Further, the augmented alpha-actin expression was observed as the degenerative process progressed (ST: 30.3 ± 5.0%, SC: 22.6 ± 2.7%, BP: 8.7 ± 4.0%, p < 0.05, respectively), followed by the upregulation of HSP47 (ST: 22.6 ± 2.8%, SC: 15.4 ± 2.1%, BP: 3.4 ± 1.0%, p < 0.05, respectively) and consecutive matrix accumulation.

Conclusions: The imbalance between proliferation and apoptosis with cellular phenotypical shift and subsequent matrix secretion may contribute to aortic valve stenosis and bioprosthesis degeneration. The identification of FKBP12 expression may implicate potential therapeutic strategies.

Wydane przez: Via Medica
Data wydania: 2013-06-10
Język: angielski
Profil: choroby sercowo-naczyniowe

Rodzaj: Artykuł, Dostęp: Dla wszystkich, Odpłatność: Darmowe